5V
Measured temperatures
Ambient temperature
The temperature is measured with a thermistor.
4.19 SMB Hardware Monitor
In addition to the SuperIO hardware monitor you can also connect a SMBus hardware
monitor. This chip enables you to control different voltages, temperatures and rotation
speeds in legacy-free-designs where the SuperIO is not supported.
Hardware monitor:
Winbond W83L786R
Controlled voltages
VBAT
3.3V
12V
5V
Measured temperatures
Ambient temperature
The temperature is measured with a thermistor.
Fan interface
For evaluation and control of the revolution speeds please refer to chapter 4.18.4.
4.20 Serial EEPROM on SMBus
For testing purposes a serial EEPROM (4kBit) is connected to the SMBus. To avoid
address conflicts, the address can be selected with dip switch SW1101.
4.21 Serial EEPROM on I2C-Bus
For testing purposes a serial EEPROM (4kBit) is connected to the I2C bus. To avoid
address conflicts, the address can be selected with dip switch SW1102.